The electronic expansion valve can continuously adjust the flow rate within the range of 15% - 100%, adapting to drastic changes in load demands and avoiding problems such as under - feeding or over - feeding of the refrigerant.
The variable - frequency refrigerated air dryer can adjust the output cooling capacity according to the user's air consumption. Many users' equipment does not operate at 100% load all the time. For example, a user's equipment runs at 100% load during the day but only at 66% load at night. Using a fixed - frequency refrigerated air dryer means that some energy consumption at night is unnecessary. In contrast, the variable - frequency refrigerated air dryer can perfectly save this unnecessary energy consumption and achieve energy - saving effects.
For instance, the compressor of a 200 - cubic - meter refrigerated air dryer consumes 37.1 kWh of energy per hour when running at full load (100% state) during the day. At night, when the air consumption is relatively low, the compressor consumes 26.7 kWh of energy per hour when running at partial load (66% state). Calculated based on 12 hours at night, the energy saved in one night is: (37.1 - 26.7) * 12 = 124.8 kWh, achieving a 28.03% energy saving.
Note: Our company's products are constantly being optimized, and parameters are subject to change without prior notice.